Home > JCSS Calibration

JCSS Calibration

JEMIC calibrates the in-house standards and/or measuring instrument, including the reference standards for JCSS accredited laboratory, using the primary standards of accredited calibration laboratories and/or the reference standards according to the ISO/IEC 17025 requirement as the JCSS accredited calibration laboratory.

Whenever JEMIC carries out the accredited calibration, JEMIC issues the calibration certificate with JCSS marking. This calibration certificate guarantees the calibrated results by the measuring standard that is traceable to national standards.

The calibration certificate with JCSS mark meets the requirements of international regulations, like ISO/IEC 17025, ISO9000, ISO/TS 16949, QS-9000, etc.

JEMIC carries out the accredited calibration as the JCSS accredited calibration laboratory. Regarding the accepted field, see the following table.

Calibration Services(JCSS & general calibration services)

(simplified table)

items calibration range JCSS cal. General cal. notes
best measurement capability(BMC) best accuracy(C.L.= 99%)
standard resistor 1mΩ to 100MΩ 0.3ppm(k=2) 2.5 ppm 23ºC,25ºC
dc voltage standard 1V,1.018V,10V 0.02ppm(k=2) 2.5 ppm 23ºC
standard cell 1.018V 0.02ppm(k=2) 2.5 ppm 25ºC
standard capacitor 0.001pF to 1F 0.73ppm(k=2) 1 ppm 50Hz to 1MHz
standard inductor 50μH to 10H - 0.01% 50Hz to 10kHz
inductive voltage divider   0.2ppm(k=2) 1 ppm 50Hz to 10kHz
shunt up to 10kA 25ppm(k=2) 0.01% -
voltage divider up to 1500V 1ppm(k=2) 10 ppm -
high voltage divider up to 200kV 0.003%(k=2) 0.05% -
resistance box up to 1015Ω 0.003%(k=2) 0.01% -
ac standard resistor 1mΩ to 1MΩ - 10ppm 50Hz to 1kHz
voltage calibrator up to 1000V dc:3ppm(k=2) dc:20ppm -
ac:27ppm(k=2) ac:0.02%
current calibrator up to 50A dc:5ppm(k=2) dc:20ppm -
ac:40ppm(k=2) ac:0.02%
frequency generator up to 100MHz 3.0×10-10(k=2) 1×10-8 -
digital voltmeter up to 1000V dc:3ppm(k=2) dc:50ppm -
ac:27ppm(k=2) ac:0.02%
electromechanical-indicating instruments dc:up to 50kV and 10kA
ac:up to 50kV and 12kA
- 0.04% -
electrical recorders
watt-hour meter
harmonic analyzer up to 20A, 600V fundamental-40th - 0.05% fundamental frequency:50Hz, 60Hz
oscilloscope 5mV to 200V, 10ns to 0.1s - 2% -
current transformer up to 20kA 10ppm(k=2) 0.02% 50Hz to 60Hz
0.1min.(k=2) 0.6min.
voltage transformer up to 550/√3kV 50ppm(k=2) 0.02% -
0.3min.(k=2) 0.6min.
ac-dc comparator up to 1000V, 20A V:21ppm(k=2) V:21ppm(k=2) voltage:up to 1MHz
A:40ppm(k=2) A:0.02% current:up to 1kHz
DC magnetic testing equipment dc:up to 2.5T - 50ppm -
AC magnetic testing equipment ac:up to 10mT - 0.2% -
flux meter flux:up to 10Wb - 0.05 % -
resistance thermometer -182.954ºC to 600ºC, 660.323ºC 1mK(k=2)(at 0.01ºC) 30mK -
radiation thermometer up to 2000ºC 0.30ºC(k=2) 0.5ºC -
thermocouple up to 1100ºC 0.25ºC(k=2) 1ºC -
liquid-in-glass thermometer -50ºC to 350ºC 4mK (k=2)(at 0ºC)   -
optical pyrometer 1000ºC to 2000ºC - 10ºC -
luminous intensity standard lamp 10cd to 3000cd 1.1%(k=2) 1% -
distribution temperature standard lamp 2000K to 3000K 18K (k=2) 18K -
total luminous flux standard lamp 5lm to 20000lm 1.1%(k=2) 1.1% -
illuminance meter 1lx to 3000lx 1.1%(k=2) 1% -
spectral irradiance standard lamp 250nm to 2500nm 3.1%(k=2)(at 450nm-600nm) 3.2%(k=2)(at 450nm-600nm) -
standard fluorescent lamp up to 40W - 2% -